07 Dec 19, 2012. Running the command results to something unexpected:. [email protected]:~# arcconf getconfig 1 | grep Status. In the example below the disk in failed state is [32:1], replace with the proper [enclosure_id:slot_id] in your case. When I run megacli -PDList -Aall this is the result: [[email protected] MegaCli]# megacli -PDList -Aall OSSpecificInitialize: Failed to load. 교체 작업을 해야한다. For VSM systems it's normally 0. Voltage: 3919 mV. Management Utilities Overview (LSI) Update BIOS firmware on multiple systems at once using Supermicro Update Manager (SUM) Create an Ubuntu LiveUSB with Persistence. Make sure the card is in a powered on system for a while (to charge), before you decide that it is bad. MegaCli -AdpPR -Info -aALL. This is reported by the "Full Charge Capacity" field in MegaCLI BBU output and will be updated after a learn cycle. Exit Code: 0x01. What is IPMI? The Intelligent Platform Management Interface (IPMI) is a standardized computer system interface used by system administrators for out-of-band management of computer systems and monitoring of their operation. When MegaRAID Storage Manager software is running, you can monitor and manage the status of all of the BBUs connected to controllers in the server. com is the number one paste tool since 2002. /MegaCli64 -AdpBbuCmd -a0. glensc added a commit that referenced this issue on Sep 8, 2014. 275 TB State : Optimal Strip Size : 64 KB Number Of Drives : 6 Span Depth : 1 Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU Current. Detect configuration mismatches. Exit Code: 0x01. 4Kn drive does not show up in bootable device list after OS installation. 1 Update 2 Host Battery Status does not detect BBU Failure. In some cases, you may actually need to use MegaCLI in order to find out the Drive ID's, otherwise they would load on. In the following example we have a single controller present and will pass the -a0 argument to select the controller. MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU. 1-0030 FW Version : 1. raid_level ( int) - specifies the RAID level. Jan 28, 2016 · 首先介绍下Linux系统本身查看. Mar 07, 2018 · Status of Logical Device : Optimal “ZMM not installed” shows that this controller currently has no BBU (batterie backup unit) installed, a BBU can be installed at any time as an upgrade. 0-0023) controller with super-cap inside. We're running RAID6, so we expect to lose 2 drives to parity and get 18TB. Check status of MegaRAID controller and disks To find out whether there are any failed disks, run the command below. megacli -PDRbld -Start -PhysDrv [252:5] -a0. Type: sh installer. set Displays or modifies controller and unit settings. The number N of the Array parameter is from the "Span Reference:" line you get using MegaCli -CfgDsply -aALL, minus the 0x0 part. 22 Rebuild Priority: Medium. Our UPS couldnt handle the power outage. 硬件raid: 最佳的办法是通过已安装的raid厂商的管理工具来查看,有cmdline,也有图形界面。. Checking out the LSI site for that card, there was no CIM providers: It only had the MegaCLI tool for VMware. MegaCli -AdpPR -Info -aALL. Step#3: Use megacli to probe for BBU status and information. /MegaCli64 -adpCount. NBU 5220 Performance. 1-0030 FW Version : 1. Exit Code: 0x01 2. There should be 12 drives listed that have an OK status. Message 2 of 6. We are observing in Vsphere Client Hardware Status the "Battery" status is Normal and the respective "Host Battery Status" alarm is NOT. com is the number one paste tool since 2002. Now we get the report what is done. [[email protected] ~]#. Symptom: FMC warning for FTD: Primary Disk status is Degraded: No SMART-enabled drives present. Boot the server backup and attempt the import process, or mark the drive as Unconfigured good and then reboot, and attempt the import process again. To carry out the various steps of this guide, you must: Have a server mHG, HG, or bHG. Make sure the card is in a powered on system for a while (to charge), before you decide that it is bad. In this state, the BBU is not capable of backup operations. , there was an attempt to get back a RAID 5 array back online; One-time multiple drives failure. Valid arguments: 0, 1, 5, 6 or 10. BatteryType: BBU. Import foreign config. 23-1 BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn. Current: 0 mA. After all mysql server are running on all servers. galera_new_cluster. In this article you will find a collection of useful commands to administer your MegaRAID controller. Anyone who has ever had to work with the LSI RAID controllers knows that the MegaCLI provided by LSI is the most cryptic command line utility in existence. 1 Update 2 Host Battery Status does not detect BBU Failure. Pour mon vieux serveur Dell PowerEdge 1950 mais aussi pour tous les serveurs équipé de carte PERC/LSI dont les cartes et disques utilisent la technologie SMART (Self-Monitoring, Analysis and Reporting Technology) pour récupérer les informations. -0205 Status : Optimal BBU BBU Type : Status : Healthy Enclosure Product Id : SGPIO Type : SGPIO Status : OK PD Connector : Port 0 - 3: Slot 1. BBu auto learn failed on some server, I think it is because the BBU was Charging (Event Description: Battery relearn pending: Battery is under charge) Code: MegaCli -AdpBbuCmd -GetBBuStatus -a0. MegaRaid Storage Manager installs to /usr/local/MegaRAID Storage Manager, while the cli installs via rpm to /opt/MegaRAID/MegaCli. * The number N of the array parameter is the Span Reference you get using MegaCli -CfgDsply -aALL and the number N of the row parameter is the Physical Disk in that span or array starting with zero (it's not the physical disk's slot!). An intelligent BBU (iBBU) has built-in functionality to charge the battery pack automatically and to communicate battery status information such as, voltage, temperature, and current, to the host computer system. id) Look in the OSD logs (systemctl status [email protected] CIMC sais that the virtual drive has a moderate fault state, cache is degraded and capacitance is at 0%. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. What follows are the commands I found useful when trying to physically identify a failed disk and then replace it. 2) check particular disk: # MegaCli64 -PDRbld -ShowProg -physdrv [245:11] -aALL. Create RAID 10 Device (Virtual Drive) Creating raid 10 device is different because we have to write the exact pairs for RAID 1 and over them there is going to be RAID 0. 硬件raid: 最佳的办法是通过已安装的raid厂商的管理工具来查看,有cmdline,也有图形界面。. Creating a new hurdle for spouses of U. Hi, I'm having a LSI MegaRaid SAS 9271-8i running a RAID1, so far so good. Double Click on "VzSpeedOptimizer100. We have several hosts running on Cisco UCS C210M2 with LSI MegaRaid SAS 9261-8i and ESXi 4. no appliance logs (e. [[email protected] ~]#. Pour mon vieux serveur Dell PowerEdge 1950 mais aussi pour tous les serveurs équipé de carte PERC/LSI dont les cartes et disques utilisent la technologie SMART (Self-Monitoring, Analysis and Reporting Technology) pour récupérer les informations. 07 Dec 19, 2012. MegaCli Using write through instead of write back. The number N of the Array parameter is from the "Span Reference:" line you get using MegaCli -CfgDsply -aALL, minus the 0x0 part. This turns out. Since you only have megacli available in the Rescue system, you can also get it quickly for your main system afterwards. MegaCLI Scripts and Commands. This paper provides documentation to help manage the PERC6/i with MegaCli in a Solaris10 environment. In no particular order. ONT box is discharging the battery in the BBU due to lack of charging. What I dont get is the BBU Status; If I query it with: storcli /c0 /bbu …. Then run the command with all the data including the adapter number which is 0 standard. When you replace a hard disk, the disk must be acknowledged by the RAID controller before you can use it. Input example: storcli /c0/bbu show status storcli /cx/bbu start learn This command starts the BBU learning cycle. You must contact QNAP immediately if the system detects that the BBU is malfunctioning. Welcome to megacli-python's documentation! ¶. Unconfigured Bad - A hard drive that is no longer part of an array and that is known to be bad. This will return a detailed status of all LSI MegaRAID controllers on this system, including the status of their disks. In no particular order. For every execution of the megacli-binary a line shows up in the kern. After turning everythink on all VMs are working. SCGCQ00295052 (DFCT) - Change BBU Mode description for Liberator batteries. megacli -PDList -aALL lists all disks and enclosures. The dependent library libsysfs. Check the firmware version on the card too. The packages comes with a python wrapper around megacli and an initscript that periodic run this wrapper to check status. We are observing in Vsphere Client Hardware Status the "Battery" status is Normal and the respective "Host Battery Status" alarm is NOT. Rebuild - A disk drive where data is written to restore full redundancy to a virtual disk. you can get a report of whats happened with the failed drive with this command (if there is anything to report) megarc -pdfailinfo -a0 -chall -idall You can try to turn the drive on in a failed state by issuing this command. For systems with remote mount BBU, the system was not shut down at the end of " Step 1: Prepare the Disk Controller BBU for Removal ". Double Click on "VzSpeedOptimizer100. Hi, We changed some BBU on some of our M5015 cards last month. Would be nice, if the message tells me, why the check is critical. Cache Status: OK Battery/Capacitor Status: Failed. Moritz Mertinkat has also put together a MegaCli64 PDF cheat sheet. db1048 is lagging behind: The reason for it looks like a faulty BBU which has changed the RAID policy to WriteThrough. Type: sh installer. Hi, I'm having a LSI MegaRaid SAS 9271-8i running a RAID1, so far so good. Still works on 6. Hint: look at "Firmware state" line in PDInfo output. 05-31-2013 11:28 AM. js维护者退出,项目的未来成疑; 大规模Neo4j集群中的因果一致性; Nginx访问日志切割脚本; CentOS 7配置iptables; CentOS6/7手动扩展PHP的IMAP模块; Nginx主要功能及使用. Would be nice, if the message tells me, why the check is critical. 查看電池容量(Display BBU Capacity Information) MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuCapacityInfo –aALL. [prev in list] [next in list] [prev in thread] [next in thread] List: linux-poweredge Subject: Re: MegaCli and Linux /dev/sd* From: Stephen Dowdy Date: 2009-05-05 16:53:02 Message-ID: 4A006EEE. ==Create RAID 10 Device (Virtual Drive)== Creating raid 10 device is different because we have to write the exact pairs for RAID 1 and over them there is going to be RAID 0. It keeps a file with latest status and thus is able to detect RAID status changes and/or. The server is PowerEdge R720. 5000707 ucar ! edu [Download RAW message or body] Tom Limoncelli wrote, On 05/05/2009 09:19 AM: > Does anyone know how /dev/sd? relat. /MegaCli64 -LdPdInfo -a0. FreeBSD - Megacli - DELL PERC 6i 4 februarie 2015 22 octombrie 2017 Bogdan Turcanu Niciun comentariu Dell , freebsd , megacli , PERC 6i Dacă aveți un server DELL cu controler PERC 6i, atunci megacli vă poate ajuta la configurarea și controlul acestuia. megacli -PDOnline -PhysDrv [1:4] -a0. Example finding failed disk and blinking the led on it. 2 Please ensure that libsfs is present in the system. MegaCli是一个非常有用的工具,无论是创建raid、获取raid信息还是修改raid设置。. Install megaraid-status and megacli. 5倍 大于8G给8G/ 所有. The number N of the row parameter is the Physical Disk in that span or array starting with zero (it can be but is not always the physical disk's slot!). The number N of the Array parameter is from the "Span Reference:" line you get using MegaCli -CfgDsply -aALL, minus the 0x0 part. section of www. LSI has opted to keep all their drivers and software proprietary. /opt/MegaRAID/MegaCli> sudo. When I run 'smartctl -i -d sat+megaraid,2' I do get S. Now we get the report what is done. In no particular order. 2 Please ensure that libsfs is present in the system. MegaRaid Storage Manager installs to /usr/local/MegaRAID Storage Manager, while the cli installs via rpm to /opt/MegaRAID/MegaCli. Nov 23, 2015 · Specification hints were got from MegaCli logs: Specification hints were got from MegaCli logs: BBU status for Adapter: BatteryType: iBBU Voltage: 5744 mV Current: 350 mA Temperature: 35 C Battery State: Degraded(Need Attention) A manual learn is required. Temperature: 47 C. If a login shows up continue with step 3, otherwise continue with step 2. 1 Display BBU Information 1-14 1. mbakman May 15, 2012 11:46 AM. xx status" and "ceph daemon osd. FreeBSD has great support for LSI MegaRAID adapters, until you try to monitor them, or get their status. Introduction. "Open File - Security Warning" window. MegaCli -AdpBbuCmd -aAll = view info about battery backup unit 3. # MegaCli -ShowSummary -a0. Please contact Veritas technical support for further assistance with a BBU replacement. You will see something like this. 7 Cisco Fire Linux OS v6. 8 Battery Backup Unit-Related Properties 1-14 1. Make "Failed State" in "Unconfigured(BAD)" megacli -pdmarkmissing -physdrv[32:1] -aAll. Start to troubleshoot in this order: Look in the monitor logs (systemctl status [email protected] Then it mentions that you might need to power cycle it, and check again. 5 Display Current BBU Properties 1-16 1. Your output will be lengthy - but look for the line below to know if you need to replace your BBU. Jul 08, 2019 · 查看電池狀態信息(Display BBU Status Information) MegaCli -AdpBbuCmd -GetBbuStatus -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuStatus -aALL. sh ; You should now be able to use the MegaCli. id) Look in the OSD logs (systemctl status [email protected] 0 or later: Log in as the root user. 硬件raid最佳的办法是通过已安装的raid厂商的管理工具来查看,下面安装MegaCLI工具查看. Message 2 of 6. Knowledge Base On the Linux OS, run 4. xmcli (tech)> show-bbus Name Index Model Serial-Number Power-Feed State Connectivity-State Enabled-State Input Battery-Charge BBU-Load Voltage FW-Version Part-Number Brick-Name Index Cluster-Name Index Outlet1-Status Outlet2-Status X1-BBU 1 Eaton 5P 1550 Gxxxxxxxxx PWR-A healthy connected enabled on 92 24 204 02. Look for the "Device Present" s= ection, which looks like this for a RAID array without any problems:. I'd like to use DSA, if possible, to see which systems show a failed battery. Jun 14, 2016 · MegaCli -PDList -aAll 【显示所有的物理信息】. Example finding failed disk and blinking the led on it. Cambiar la política de cache de controladora RAID con MegaCLI. Check status of MegaRAID controller and disks. This is a simple Python library that wraps around MegaCli to provide an OO interface. Enclosure Device ID: 252. 14 Hardware Controller ProductName : LSI MegaRAID SAS 9260CV-8i(Bus 0, Dev 0) SAS Address : 500605b00582ca90 FW Package Version: 12. I use MegaCLI on couple of newer IBM's. Step 1: check the BBU logs for a "Persistent fault" message. If you see this screen, click on "Run" in the. 目前我接受任何方法来实现这些目标。 这两个服务器在CentOS 6. In the example below we will cover replacing a failed disk from a raid 5 that has three disks total. 0 or later: Log in as the root user. So I somehow got omreport to work > and wrote some wrapper scripts and left it at that. One of my clients has experienced a rash of failed RAID batteries. 1 not available. after our latest kernel-update from 4. You should run the script on the host to be monitored since it only generates template items and notification. Start to troubleshoot in this order: Look in the monitor logs (systemctl status [email protected] The area we were to most benefit was with VMware backups. Failed to follow the product. StorCLI is somewhat similar to MegaCLI, but allows you to append " J" to every command to have the response returned in JSON. 3 Display BBU Capacity 1-15 1. Start to troubleshoot in this order: Look in the monitor logs (systemctl status [email protected] MegaCli -AdpPR -Info -aALL. " With the LSI MegaRID SAS 9261, ther is no issue. It should return:. after our latest kernel-update from 4. New drive in place with same target number. We can follow below steps to rebuild the disk in MegaRaid if it did not start automatically. Check the status of an LSI raid card battery backup unit. This is a good setting if your raid card's BBU charger is bad, if you do not want or can't to replace the BBU or if you do not want WriteThrough enabled during a BBU relearn test. -pdlistdisplays a WWN value for each physical drive, but that doesn't help much. samm2's suggested solution, option 'megaraid,1 - megaraid32' did work for me. Current: 0 mA. "If you want to force a drive into Fail status to trigger a rebuild, right-click the drive icon, and select Make Drive Offline. This is reported by the "Full Charge Capacity" field in MegaCLI BBU output and will be updated after a learn cycle. I can manage it with megacli no problem. MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU. We are observing in Vsphere Client Hardware Status the "Battery" status is Normal and the respective "Host Battery Status" alarm is NOT. Adapter #0 Number of Virtual Disks: 1 Virtual Drive: 0 (Target Id: 0) Name :Virtual Disk 0 RAID Level : Primary-6, Secondary-0, RAID Level. For VSM systems it's normally 0. after our latest kernel-update from 4. 伺服器大多是LSI的MegaRAID卡,MegaCli相容伺服器命令 Get BBU Status Failed. 6 x86_64 megactl 0. This morning I came to reconfigure a raid array on an old Dell Perc5i with the LSI MegaRAID CLI tool megacli, and whilst displaying information and removing an old LD appeared to work fine, I was greeted with the following when trying to add a new LD: # megacli -CfgSpanAdd -r10 -Array0[10:2,10:3] Array1[10:6,10:7] WB RA Direct CachedBadBBU -a0 Adapter 0: Configure Adapter Failed Exit Code: 0x03. Performing the following challenges: http-01 challenge for tms. you would reset the ONT if necessary but after a power outrage the ont should boot back up on its own. We're running RAID6, so we expect to lose 2 drives to parity and get 18TB. /MegaCli64 -adpCount. MegaCli is a software for managing and maintaining hardware RAID. Hello fellow zabbixers! I thought that it would be nice to get notified about raid disk failures by zabbix, so I've put together a small bash script to generate monitoring XML templates for LSI and Symbios MegaRAID controllers using the MegaCli executable downloadable from www. /MegaCli64 -AdpBbuCmd -aAll. 首先下载MegaCli,解. Change back to the login screen with ALT+F2. DB node's where the Megacli status is shown as "Firmware state: (Unconfigured Bad)" or "Firmware state: Failed" preceded by logged errors indicating the drive was Failed or Predictive Failed: Case R4. megaclisas-status is a wrapper script around megacli that report summarized RAID status with periodic checks feature. MegaCli shows no BBU errors, while megactl shows battery FAULT. 1) show all disks parameters: # MegaCli64 -PDList -aALL. Looking some though some of the other articles on here, is only occurs when the battery is faulty. DB node's where the "Predictive Failure Count" is >0 even if the drive status shows as "Online". # MegaCli -ldinfo -Lall -aall Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3 Size : 7. For every execution of the megacli-binary a line shows up in the kern. Then run the command with all the data including the adapter number which is 0 standard. Port's Linkspeed: 6. T alert : No ===== Firmware state가 정상일때는 Online, Spun Up이며, Failed이면 디스크에 장애가 발생했기 때문에. #cat /proc/scsi/scsi. /usr/bin/MegaCLI could not get RAID Adaptor list sda status: FAILED!. 1g and CIMC firmware 1. status changed; resolution set. MegaCLI on LSI MegaRAID 9260-8i -- PDMakeJBOD is no bueno. Failed to follow the product. MegaCli -AdpGetProp PatrolReadRate -aALL. Write down what you think the current state of the system is and what change you want to make. MegaCli shows no BBU errors, while megactl shows battery FAULT. MegaCli64 -CfgDsply -a0 ===== Adapter: 0 Product Name: LSI 2108 MegaRAID Memory: 512MB BBU: Present Serial No: ===== Number of DISK GROUPS: 3 DISK GROUP: 0 Number of Spans: 1 SPAN: 0 Span Reference: 0x00 Number of PDs: 4 Number of VDs: 1 Number of dedicated Hotspares: 0 Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID. x=the channel normally 0 y=the id of the physical drive megarc -physOn -a0 pd[x:y] you can also turn the drive off. WriteBack, ReadAdaptive, Cached, Write Cache OK if Bad BBU} PD: 0 Enclosure: 32 Slot: 0 (O) 136. BBU status for Adapter: 0. I use MegaCLI on couple of newer IBM's. 如Adaptec公司的硬件卡就可以通过下面的命令. when_failed:如果value小于等于thresh,会被设置成“failing_now”;如果worst小于等于thresh会被设置成“in_the_past”;如果都不是,会被设置成“-”。在“failing_now”情况下,需要尽快备份重要文件,特别是属性是pre-fail类型时。. MegaCLI can be downloaded from the support and download. Sep 07, 2014 · Adapter 0: Get BBU Status Failed. To reduce patrol read resource usage to 2% in order to minimize the performance impact: MegaCli -AdpSetProp PatrolReadRate 2 -aALL. Create a new RAID1 volume using SLOTA. Anyway to check the battery status run the following (note i am running 64 bit os) >. rpm Preparing. After consulting megacli and storecli documentation we can see how to do this. 常规分区/boot 1024Mswap 内存1. 查看電池容量(Display BBU Capacity Information) MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuCapacityInfo –aALL. I replaced old BBU up to new BBU, but BBU status is not changed. you would reset the ONT if necessary but after a power outrage the ont should boot back up on its own. This is optional if Step4 was skipped or failed but physical disk status shows as (U) - Unconfigured. Hi, I'm having a LSI MegaRaid SAS 9271-8i running a RAID1, so far so good. /MegaCli64 -AdpBbuCmd -aAll Adapter 0: Get BBU Status Failed. If you're using hot spares then the replaced drive should become your new hot spare drive MegaCli -PDHSP -Set -PhysDrv [E:S] -aN 6. Again to make sure of the integrity, do a scrub on the pool : # zpool scrub geekpool. You can use it to understand all the information of the current raid card, including the model of the raid card, the type of the raid array, the status of each disk on the raid, and so on. Apparently the Dell Perc 5i does similar re-branding, more on that at Using Perc 5i with ESXi 5. Exit Code: 0x01. To start a manual patrol read scan:. BBU status for Adapter: 0. 1g and CIMC firmware 1. Adapter 0: Get BBU Status Failed. When I run megacli -PDList -Aall this is the result: [[email protected] MegaCli]# megacli -PDList -Aall OSSpecificInitialize: Failed to load. MegaCli64 -CfgDsply -a0. BBu auto learn failed on some server, I think it is because the BBU was Charging (Event Description: Battery relearn pending: Battery is under charge) Code: MegaCli -AdpBbuCmd -GetBBuStatus -a0. Mar 19, 2014 · MegaCli 是一款管理维护硬件RAID软件,可以通过它来了解当前raid卡的所有信息,包括 raid卡的型号,raid的阵列类型,raid 上各磁盘状态,等等。. The dependent library libsysfs. Code: CLI Version: 8. looking for these parameters: Enclosure Device ID: 245 Slot Number: 15 and. Download MegaCli package, copy the executable from VMware folder to your host's persistent storage (use your local vmfs datastore; do not use the root partition - it uses tmpfs to minimize the writes to the flash media and the file will disappear after the reboot). Basic problem is no charging voltage from BBU to battery in the box. /MegaCli64 -pdlist -a8 | grep WWN WWN: 500051610003776C WWN: 5000516100037BFC WWN: 5000516100038090 WWN. After all mysql server are running on all servers. This post show installation of MegaCli (ServeRAID MR 10 k SAS/SATA Controller client) and two basic commands 1. A better tool for viewing the status, but changes should be made via java tool Text Based Benefit : The most efficient - tailor it to show just the information you want Common invocations of MegaCLI Get an Overview of controllers and attached disk arrays. Step#3: Use megacli to probe for BBU status and information. sh info Product Name PERC 6/i Adapter Serial No 1122334455667788 FW Package Build 6. Note that there is an open source CLI called Megactl, and while its quick and easy to use to see a quick list of your disks and their statuses, its not shown itself to be accurate when it comes to detecting whether or not a battery has failed. Moritz Mertinkat has also put together a MegaCli64 PDF cheat sheet. You can get it from LSI's website (search for MegaRAID SAS). This is a good setting if your raid card's BBU charger is bad, if you do not want or can't to replace the BBU or if you do not want WriteThrough enabled during a BBU relearn test. 22 Rebuild Priority: Medium. Management Utilities Overview (LSI) Update BIOS firmware on multiple systems at once using Supermicro Update Manager (SUM) Create an Ubuntu LiveUSB with Persistence. BBU Firmware Status:. Check status of MegaRAID controller and disks To find out whether there are any failed disks, run the command below. MegaCli64 -CfgDsply -a0 ===== Adapter: 0 Product Name: LSI 2108 MegaRAID Memory: 512MB BBU: Present Serial No: ===== Number of DISK GROUPS: 3 DISK GROUP: 0 Number of Spans: 1 SPAN: 0 Span Reference: 0x00 Number of PDs: 4 Number of VDs: 1 Number of dedicated Hotspares: 0 Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID. MegaCli Using write through instead of write back. Monitoring->Latest Data->фильтруем по требуемому хосту в. You will see something like this. Migrate a storage configuration to a different RAID level. The dependent library libsysfs. megacli -pdmakegood -physdrv [E:S] -aN. If you need to replace more than one disk, then replace them in the following order of preference: Disks on-board the appliance head unit (versus a DAC) Disks which currently have physical state of Failed, Offline, Unknown state or Missing. It keeps a file with latest status and thus is able to detect RAID status changes and/or. 软件raid:只能通过Linux系统本身来查看. In order to disable Write Through Cache please disable Write Through for failed/missing BBU. Dell服务器MegaCli命令只返回Exit Code: Ubuntu 下安装 LSI MegaCLI 磁盘阵列管理工; MySQL分库分表备份脚本; Phantom. Exit Code: 0x01. Hi, We changed some BBU on some of our M5015 cards last month. Without the battery backup unit the raid card can not guarantee data in the card's cache will be written to the physical disks if the power goes out. 6 Start BBU Learning Cycle 1-17. 2:MegaCli ##### [100%] After the installation succeded, the binaries can be found under /opt/MegaRAID/MegaCli: # cd /opt/MegaRAID/MegaCli To get the state of the battery run MegaCli64:. Verify how many server on the current cluster. Linux下查看软、硬raid信息的方法。. See full list on veritas. The dependent library libsysfs. The turnaround on recovery of these volumes is about one week. Write down what you think the current state of the system is and what change you want to make. Welcome to megacli-python's documentation! ¶. Mar 07, 2018 · Status of Logical Device : Optimal “ZMM not installed” shows that this controller currently has no BBU (batterie backup unit) installed, a BBU can be installed at any time as an upgrade. 硬件raid:查看raid的厂商,型号,级别. 32-1371 BIOS Version 2. -ldinfo doesn't print a WWN or any other identifying value. Then use megacli or MSM to view the battery status. In some cases, you may actually need to use MegaCLI in order to find out the Drive ID's, otherwise they would load on. Knowledge Base On the Linux OS, run 4. In order to use it, we've got to do a couple things to our system. The area we were to most benefit was with VMware backups. 首先介绍下Linux系统本身查看. 目前我接受任何方法来实现这些目标。 这两个服务器在CentOS 6. Replace the battery or the BBU as soon as possible Failed: Indicates that the battery failed a test. RAID setups for database: raid-10; 256k stripe; writeback cache; no read ahead; How to set up the initial raid group. [[email protected] ~]# MegaCli -AdpAllInfo -aAll Adapter #0 ===== Versions ===== Product Name : PERC 5/i Integrated Serial No : 12345 FW Package Build: 5. 红宝书知识点回顾: Linux默认策略,把没有使用的内存,都会作为缓冲区或者缓存区。 1. UCS C220 M3 with MegaRAID 9266-8i - cache degraded. In some cases, you may actually need to use MegaCLI in order to find out the Drive ID's, otherwise they would load on. ch/twiki/bin/view/FIOgroup/DiskRefPerc. # MegaCli -ldinfo -Lall -aall Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3 Size : 7. This morning I came to reconfigure a raid array on an old Dell Perc5i with the LSI MegaRAID CLI tool megacli, and whilst displaying information and removing an old LD appeared to work fine, I was greeted with the following when trying to add a new LD: # megacli -CfgSpanAdd -r10 -Array0[10:2,10:3] Array1[10:6,10:7] WB RA Direct CachedBadBBU -a0 Adapter 0: Configure Adapter Failed Exit Code: 0x03. The install should be quite easy, but LSI make us jump through a few hoops. sh info Product Name PERC 6/i Adapter Serial No 1122334455667788 FW Package Build 6. 2 Please ensure that libsfs is present in the system. Import foreign config. Type: sh installer. This is reported by the "Full Charge Capacity" field in MegaCLI BBU output and will be updated after a learn cycle. /MegaCli64 -adpCount. Initialize virtual drives. After consulting megacli and storecli documentation we can see how to do this. [email protected]:~# megacli -AdpBbuCmd -a0 BBU status for Adapter: 0 BatteryType: BBU Voltage: 4025 mV Current: 0 mA Temperature: 32 C Battery State: Degraded (Need Attention) A manual learn is required. /MegaCli64 -PDList -a0 Adapter #0 Enclosure Device ID: 32 Slot Number: 3. LSI replaced MegaCli with StorCLI / StorCLI64 and some command syntax has changed. for disable beeps:. 5000707 ucar ! edu [Download RAW message or body] Tom Limoncelli wrote, On 05/05/2009 09:19 AM: > Does anyone know how /dev/sd? relat. 0, I was able to see my drive status (and veeam one could alert me), and with my WIndows VM, I had LSI MSM and I was able to configure the raid card. LSI MegaRaid LSI MegaRaid Hardware notes Software notes Ubuntu Installation Running the CLI Commands via the CLI Getting all information about the Adapter Silencing an Alarm To find a faulty drive Identify a drive Spare Drive and Hot Spares Replacing a faulty drive Enclosure Information Battery State Logs Hardware notes LSI MegaRaid controllers are available…. The program is a text based command line interface (CLI) and is comprised of a single static binary file. Oct 12, 2011 · Note that there is an open source CLI called Megactl, and while its quick and easy to use to see a quick list of your disks and their statuses, its not shown itself to be accurate when it comes to detecting whether or not a battery has failed. Notes: There are 12 drives of about 1. Firmware state: Rebuild. 6 Start BBU Learning Cycle 1-17. [email protected] :MegaCli >. Avaya may check the status of RAID battery from the System platform as follows: 1. You should run the script on the host to be monitored since it only generates template items and notification. Specification hints were got from MegaCli logs: Specification hints were got from MegaCli logs: BBU status for Adapter: BatteryType: iBBU Voltage: 5744 mV Current: 350 mA Temperature: 35 C Battery State: Degraded(Need Attention) A manual learn is required. Still works on 6. We can check the controller again. 05-31-2013 11:28 AM. McAfee SIEM Enterprise Security Manager (ESM) 11. Megacli show rebuild status. Displaying the disk allows a user to make sure that the enclosure and slot numbers are correct. Checking on the status of your raid cards battery backup unit (BBU) is a simple process by using the following MegaCli command: $ MegaCli64 -AdpBbuCmd -a. 425556] megaraid_sas 0000:03:00. When I run 'smartctl -i -d sat+megaraid,2' I do get S. T alert : No ===== Firmware state가 정상일때는 Online, Spun Up이며, Failed이면 디스크에 장애가 발생했기 때문에. BBu auto learn failed on some server, I think it is because the BBU was Charging (Event Description: Battery relearn pending: Battery is under charge) Code: MegaCli -AdpBbuCmd -GetBBuStatus -a0. [email protected]:~# arcconf getconfig 1 | grep Status. Temperature: 47 C. Example: megacli -CfgSpanAdd -r10 -Array0 [245:2,245:3] -Array1 [245. DB node's where the Megacli status is shown as "Firmware state: (Unconfigured Bad)" or "Firmware state: Failed" preceded by logged errors indicating the drive was Failed or Predictive Failed: Case R4. -check Controller status. The following are the main causes of RAID 5 drive collapse: RAID partition absence; Using a failed disk; e. Slot Number: 0. Avaya may check the status of RAID battery from the System platform as follows: 1. Exit Code: 0x00 We can see that virtual drive 2 created. Controller Count: 0. I can't get my LSI 8708EM2 (detected as a 1078) to show drive status. instead of the normal 2%. FreeBSD - Megacli - DELL PERC 6i 4 februarie 2015 22 octombrie 2017 Bogdan Turcanu Niciun comentariu Dell , freebsd , megacli , PERC 6i Dacă aveți un server DELL cu controler PERC 6i, atunci megacli vă poate ajuta la configurarea și controlul acestuia. In the E-Mail you got from Hetzner there is also a login included for their Download-Area. #dmesg | grep -i raid. The NetBackup 5220 Appliance DataCollect. Alarm or BBU) 0x23 Item not found 0x24 LD drives are not within an enclosure 0x25 PD CLEAR operation is in progress 0x26 Unable to use SATA(SAS) drive to replace SAS(SATA) 0x27 Patrol Read is disabled 0x28 Given row index is invalid 0x2d SCSI command done, but non-GOOD status was received - see mf. I was running MegaCli to get BBU info, but suddently it failed and return errors: # MegaCli -AdpBbuCmd -aALL. Only the last drive to have failed will likely import, but it does mean that this last drive needs to be healthy enough to get the RAID array back to a degraded or non-critical state. 当然更多情况是没有安装相应的管理工具,只能依靠Linux本身. Without the battery backup unit the raid card can not guarantee data in the card's cache will be written to the physical disks if the power goes out. #cat /proc/scsi/scsi. Still I am concerned that it might happen that I cannot boot OS and I need to manage RAID. 在想获得更多raid信息及硬盘细节问题等细节上,得到了更多底层的数据. Nov 18, 2018 · 0. What follows are the commands I found useful when trying to physically identify a failed disk and then replace it. In order to use it, we've got to do a couple things to our system. -pdlistdisplays a WWN value for each physical drive, but that doesn't help much. While replace BBU the server proliang 380 G5 was power off. Configuration Related. cat /proc/mdstat. We also using other flag of megacli command. It seems that megacli has an issue with kernels >= 3. If you are using image version 11. The install should be quite easy, but LSI make us jump through a few hoops. Anyway to check the battery status run the following (note i am running 64 bit os) >. The NetBackup 5220 Appliance DataCollect. NBU 5220 Performance. Drive has flagged a S. Pastebin is a website where you can store text online for a set period of time. 查看電池容量(Display BBU Capacity Information) MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuCapacityInfo –aALL. For every execution of the megacli-binary a line shows up in the kern. Nov 23, 2015 · Specification hints were got from MegaCli logs: Specification hints were got from MegaCli logs: BBU status for Adapter: BatteryType: iBBU Voltage: 5744 mV Current: 350 mA Temperature: 35 C Battery State: Degraded(Need Attention) A manual learn is required. 07,都会出现错误。 这是Megacli -PDList -aAll的前三个驱动器的输出。 这显示了两个坏的驱动器和一个好的驱动器。. megacli -PDOffline -PhysDrv [32:15] -a0 -nolog Adapter: 0: Failed to change PD state at EnclId-32 SlotId-15. This is just in a little test machine with a few drives. In some cases, you may actually need to use MegaCLI in order to find out the Drive ID's, otherwise they would load on. Mark the drive as missing MegaCli -PDMarkMissing -PhysDrv [E:S] -aN 3. This will return a detailed status of all LSI MegaRAID controllers on this system, including the status of their disks. This post show installation of MegaCli (ServeRAID MR 10 k SAS/SATA Controller client) and two basic commands 1. Failed - A disk drive that is part of a virtual disk, but has failed and is no longer usable. In the event that the BBU has failed and the Full Charge Capacity is permanently set to 0, the following steps must be taken: Apply the firmware update described above, either with an EEB or with a release update. I've been following this tutorial HERE as I've honestly never used MegaCLI until now. 818 TB State : Optimal Strip Size : 256 KB Number Of Drives : 3 Span Depth : 1 Default Cache Policy : WriteBack, ReadAhead, Direct, No Write. Drive actually failed. Dec 22, 2011 · Utilites Download DOS Put on Bootable DOS USB or CD Windows Run 'Command' prompt in Adminstrator mode and then run the utilities MegaCLI SAS RAID Management Tool Ver 8. 2 Please ensure that libsfs is present in the system. #cat /proc/mdstat. /MegaCli64 -adpCount. Recently was getting poor performance from the database and stumbled across that the current cache policy is WT but the default cache policy is WB. It works fine with exception that I cannot get into configuration during the boot. We recently deployed a 5220 appliance into our environment as it was to be the savior in our battle against a backup window we were no longer able to meet. When I run 'smartctl -i -d sat+megaraid,2' I do get S. Code: CLI Version: 8. This check monitors the state of the battery of a raid controller in a Dell device. WriteBack, ReadAdaptive, Cached, Write Cache OK if Bad BBU} PD: 0 Enclosure: 32 Slot: 0 (O) 136. Hi everybody, I bought Perc 6/e adapter on Ebay. Nov 18, 2018 · 0. In order to disable Write Through Cache please disable Write Through for failed/missing BBU. At the console, press ALT+F1 to get to the ESXi shell. Adapter 0: Get BBU Status Failed. Management Utilities Overview (LSI) Update BIOS firmware on multiple systems at once using Supermicro Update Manager (SUM) Create an Ubuntu LiveUSB with Persistence. While replace BBU the server proliang 380 G5 was power off. Aug 20, 2013 · megacli reports a missing BBU as Critical, but in the check result the missing BBU is not mentioned. This command shows the BBU Learn properties for a controller. You should run the script on the host to be monitored since it only generates template items and notification. Temperature: 47 C. T alert : No ===== Firmware state가 정상일때는 Online, Spun Up이며, Failed이면 디스크에 장애가 발생했기 때문에. "If you want to force a drive into Fail status to trigger a rebuild, right-click the drive icon, and select Make Drive Offline. Inside the tarball or zip file you'll find an RPM archive. Aug 6, 2010. Any idea? Thanks in. id) Check Disk Health (SMART) Check Network Health (Network diagnostic tools) Check the details at /var/log/syslog. There is a LSI MegaRaid 9266-8i (Firmware 23. citizens and green card holders (permanent residents), U. BBU Firmware Status:. Blink Failing drive. In the E-Mail you got from Hetzner there is also a login included for their Download-Area. If I let the ,2 run through a sequence like from 2-14 I do get individual information about all my 12 disks. LSI has opted to keep all their drivers and software proprietary. When you replace a hard disk, the disk must be acknowledged by the RAID controller before you can use it. " With the LSI MegaRID SAS 9261, ther is no issue. It seems that megacli has an issue with kernels >= 3. I've followed the tutorial exactly, enabled JBOD on the. After the reboot, and trying the command Megacli -adpfacdefset -a0, I get the below error: DOS/32A warning (9004): mouse initialization failed DOS/32A warning (9001): no extended memory has been allocated DOS/32A fatal (4003): not enough extended memory to load application exec "C:\MEGACLI. -check Drive Write Cache (should be disabled) 6. 1 Build 582267. Install using the rpm command # rpm -ivh rpms/MegaCli-3. 2、参考地址里面写的主要监控方式是分区,这样的如果我一个磁盘阵列12块硬盘,这些硬盘就划了一个分区,这样监控没有. Over 166,000 such requests were filed in Fiscal Year 2017, according to USCIS data. BatteryType: BBU. Port's Linkspeed: 6. Aug 6, 2010. settime = Set the raid card's time to the current system time. /MegaCli64 -LdPdInfo -a0. Battery State : Operational. Tens of thousands of happy customers have a Proxmox subscription. I'd like to use DSA, if possible, to see which systems show a failed battery. Alarm or BBU) 0x23 Item not found 0x24 LD drives are not within an enclosure 0x25 PD CLEAR operation is in progress 0x26 Unable to use SATA(SAS) drive to replace SAS(SATA) 0x27 Patrol Read is disabled 0x28 Given row index is invalid 0x2d SCSI command done, but non-GOOD status was received - see mf. I stumbled upon this gem FreeBSD RAID Monitoring by Nico Schottelius. 2 Select BIOS Status Options 1-13 1. 05-31-2013 11:28 AM. Exit Code: 0x37. [email protected]:~# megacli -AdpBbuCmd -aAll BBU status for Adapter: 0 BatteryType: BBU Voltage: 3497 mV Current: 0 mA Temperature: 45 C Battery State: Degraded (Need Attention) A manual learn is required. In the example below the disk in failed state is [32:1], replace with the proper [enclosure_id:slot_id] in your case. I've been following this tutorial HERE as I've honestly never used MegaCLI until now. LSI Command Line Interface cross reference MegaCLI vs tw_cli vs Storcli. Raid controller events at this point are not captured in the Cisco Unified Computing System (UCS) System Event Logs (SEL) or Onboard Failure Logging (OBFL) logs. The number of RAID volumes configured on a PERC 6/i, properties and status for each volume, and the information and status for constituent member disks is provided by entering the following command: # MegaCli -ldpdinfo -a0. Input example: storcli /c0/bbu show status storcli /cx/bbu start learn This command starts the BBU learning cycle. I can't get my LSI 8708EM2 (detected as a 1078) to show drive status. In the event the source link ever 404s, a mirror can be found here. Exit Code: 0x01. Where 252 and 5 in [252:5] are the Enclosure Device ID and slot number respectively which you get from megacli or megasasctl, 0 in Array0 is the array number, 2 in row2 is the number of the drive in the RAID array, and 0 in a0 represents the adapter. 07,都会出现错误。 这是Megacli -PDList -aAll的前三个驱动器的输出。 这显示了两个坏的驱动器和一个好的驱动器。. Recent Posts. Anyone who has ever had to work with the LSI RAID controllers knows that the MegaCLI provided by LSI is the most cryptic command line utility in existence. 2、参考地址里面写的主要监控方式是分区,这样的如果我一个磁盘阵列12块硬盘,这些硬盘就划了一个分区,这样监控没有. x=the channel normally 0 y=the id of the physical drive megarc -physOn -a0 pd[x:y] you can also turn the drive off. Specification hints were got from MegaCli logs: Specification hints were got from MegaCli logs: BBU status for Adapter: BatteryType: iBBU Voltage: 5744 mV Current: 350 mA Temperature: 35 C Battery State: Degraded(Need Attention) A manual learn is required. Pastebin is a website where you can store text online for a set period of time. citizens and green card holders (permanent residents), U. 0 milestone on Sep 8, 2014. 425556] megaraid_sas 0000:03:00. T= his will return a detailed status of all LSI MegaRAID controllers on this s= ystem, including the status of their disks. Oracle Exadata Storage Server Software - Version 11. 637 TB Sector Size : 512 Is VD emulated : No Parity Size : 1. This command shows the BBU Learn properties for a controller. show status like 'wsrep_cluster_size';. Apparently the Dell Perc 5i does similar re-branding, more on that at Using Perc 5i with ESXi 5. FreeBSD has great support for LSI MegaRAID adapters, until you try to monitor them, or get their status. Failed to follow the product. Then another disk goes "pop" resulting in a failed RAID status. For that reason, the cache content is often protected by a BBU or BBM (depending on the manufacturer, either the term Battery Backup Unit (BBU) or Battery Backup Module (BBM) is used). MegaRaid Storage Manager installs to /usr/local/MegaRAID Storage Manager, while the cli installs via rpm to /opt/MegaRAID/MegaCli. Port-1 : Port status: Active. On db3 bootstrap the new cluster. Drive has flagged a S. 米鼠网-国内唯一的复杂性项目在线交易平台,其服务的种类包括了政府采购、软件项目、人才外包、猎头服务、综合项目等。米鼠网对于买家而言,提供了强大的供应商资源,并大幅降低了成本;对乙方而言,则提供了无限的商业机会,并将他们的专业技能转换成为现金收入. In the example below the disk in failed state is [32:1], replace with the proper [enclosure_id:slot_id] in your case. megaclisas-status. Symptom: FMC warning for FTD: Primary Disk status is Degraded: No SMART-enabled drives present. /MegaCli64 -AdpBbuCmd -aAll. We are observing in Vsphere Client Hardware Status the "Battery" status is Normal and the respective "Host Battery Status" alarm is NOT. Cache Status: OK Battery/Capacitor Status: Failed. To disable automatic patrol read: MegaCli -AdpPR -Dsbl -aALL. Examine drives on one adapter. 275 TB State : Optimal Strip Size : 64 KB Number Of Drives : 6 Span Depth : 1 Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU Current. citizens and green card holders (permanent residents), U. Check with Enclosure/slot drive is degraded. for disable beeps:. We got the information: "There is no BBU currently installed in you system or your BBU has failed. Without the battery backup unit the raid card can not guarantee data in the card's cache will be written to the physical disks if the power goes out. ONT box is discharging the battery in the BBU due to lack of charging. Temperature: 47 C. Replace the BBU. The disk drives in each database server are controlled by a MegaRAID SAS disk controller. 1 MegaCli 8. Install using the rpm command # rpm -ivh rpms/MegaCli-3. MegaRAID Controller Alarm Still Active After VD Rebuild Completes. 常规分区/boot 1024Mswap 内存1. Hint: look at "Firmware state" line in PDInfo output. 5000707 ucar ! edu [Download RAW message or body] Tom Limoncelli wrote, On 05/05/2009 09:19 AM: > Does anyone know how /dev/sd? relat. id) Check Disk Health (SMART) Check Network Health (Network diagnostic tools) Check the details at /var/log/syslog. MegaCli command on LSI Raid --BBU,write policy and disk cache policy 首页 分类 标签 留言 关于 订阅 2016-03-17 | 分类 Storage | 标签 megacli 引言. setdefaults = Set preferred default settings for new raid setup. It works fine with exception that I cannot get into configuration during the boot. The field we need to watch is Firmware State : Failed. 這種情況,如果沒有修改預設WriteCache OK if Bad BBU模式或者No-Battery Write Cache: Enabled,在電池損壞時會轉換成WT模式。從而導致IO非常高。. #cat /proc/scsi/scsi. The server is PowerEdge R720. 1) show all disks parameters: # MegaCli64 -PDList -aALL. settime = Set the raid card's time to the current system time. An intelligent transportable BBU (iTBBU) combines a battery and memory, and moves cached data from a failed controller. Port's Linkspeed: 6. 软件raid:只能通过Linux系统本身来查看. After the reboot, and trying the command Megacli -adpfacdefset -a0, I get the below error: DOS/32A warning (9004): mouse initialization failed DOS/32A warning (9001): no extended memory has been allocated DOS/32A fatal (4003): not enough extended memory to load application exec "C:\MEGACLI. Symptom: FMC warning for FTD: Primary Disk status is Degraded: No SMART-enabled drives present. Current: 0 mA. The battery backup or power reserve simply keeps your Verizon phone working for 8 hours or more during a power outrage. Start Mysql server on the other servers (db1 and db2) systemctl start mysql. 1、如果zabbix官方提供监控模板,直接导入应用就行,像我前面写过的dell R720等服务器。. Modern RAID controllers have integrated caches for increasing performance. To reduce patrol read resource usage to 2% in order to minimize the performance impact: MegaCli -AdpSetProp PatrolReadRate 2 -aALL. May 27, 2014 · Command MegaCli -AdpBbuCmd -aALL return error. The LSI software in windows sees the BBU fine, health status is showing as OK but it shows as Degraded and needs attention (see below) This stops the write policy going to 'Write Back' which is what I need running to get the fast write speeds but its not kicking in as it says the BBU is discharged (see below) This controller has a learn feature. Scan devices connected to the controller. This indicates a test failure state that cannot be cleared in the field. FW error description: The required hardware component is not present. [email protected]:~# megacli -AdpBbuCmd -aAll BBU status for Adapter: 0 BatteryType: BBU Voltage: 3497 mV Current: 0 mA Temperature: 45 C Battery State: Degraded (Need Attention) A manual learn is required. The server is PowerEdge R720. So the LSI MegaRAID SAS 1078 Controller is basically the same thing as the MegaRAID 8704ELP Model. In the event that the BBU has failed and the Full Charge Capacity is permanently set to 0, the following steps must be taken: Apply the firmware update described above, either with an EEB or with a release update. 硬件raid: 最佳的办法是通过已安装的raid厂商的管理工具来查看,有cmdline,也有图形界面。. BBu auto learn failed on some server, I think it is because the BBU was Charging (Event Description: Battery relearn pending: Battery is under charge) Code: MegaCli -AdpBbuCmd -GetBBuStatus -a0. 那raid卡的BBU电池模块就有问题,或者就没电池。 显示当前BBU属性 # MegaCli -AdpBbuCmd. Get your subscription! The Proxmox team works very hard to make sure you are running the best software and getting stable updates and security enhancements, as well as quick enterprise support. Raid setup at Wikimedia. Querying the RAID card. /MegaCli64 -PDList -a0 Adapter #0 Enclosure Device ID: 32 Slot Number: 3. While replace BBU the server proliang 380 G5 was power off. It should return:.